Great as spare part
for scales or for commercial, industrial and experimental
purpose. It's economical and highly accurate.
For several years, we have manufactured load cells for our
scales and supplied internationally for other businesses and
manufacturers.
OUTLINE DIMENSIONS
Dimension (mm)
|
L
|
L1
|
L2
|
L3
|
L4
|
H
|
H1
|
B
|
B1
|
D
|
M
|
|
130
|
15.8
|
25.4
|
76.2
|
54.2
|
31.8
|
15.8
|
31.8
|
34
|
13.5
|
M12×1.75
|
SPECIFICATION
Accuracy class
|
|
C3
|
Approval
|
|
OIML R60 C3
|
Maximum number of
verification intervals
|
n max
|
3000
|
Minimum load cell
verification interval
|
v min
|
Emax/10000
|
Combined error
|
(%FS)
|
≤±0.020
|
Creep
|
(%FS/30min)
|
≤±0.016
|
Temperature effect on
sensitivity
|
(%FS/10℃)
|
≤±0.011
|
Temperature effect on
zero
|
(%FS/10℃)
|
≤±0.015
|
Output sensitivity
|
(mv/v)
|
2.0 ±0.002
|
Input resistance
|
(Ω)
|
350±3.5
|
Output resistance
|
(Ω)
|
351±2
|
Insulation resistance
|
(MΩ)
|
≥ 5000(100VDC)
|
Zero balance
|
(%FS)
|
1.5
|
Temperature, compensated
|
(℃)
|
-10~+40
|
Temperature,allowed
|
(℃)
|
-35~+65
|
Excitation, Recommended
|
(V)
|
5~12(DC)
|
Excitation,Max
|
(V)
|
18(DC)
|
Safe overload
|
(%FS)
|
120
|
Ultimate overload
|
(%FS)
|
150
|
|